Giá: Yêu cầu báo giá
Hàng có sẵn: Model: TIC20 Xuất sứ: Chi tiết sản phẩm:The LogTag TIC20 is an irreversible electronic temperature indicator for use in monitoring temperature & time statistics in pharmaceutical transport applications of up to 20 days duration and is factory pre-configured to monitor a range of standard vaccines. Provides clear indication of temperature history/alarm status at all times. Push button Start and Stop. Push Review button to display daily statistics in sequence. Data can be downloaded via an interface cradle to LogTag Analyzer software if required.
Current temperature, elapsed time, load status, monitoring status and battery condition can all be seen at a glance at any time during the trip. On arrival at the destination, monitoring can be stopped and the user can then review time and temperature statistics for each day of the trip, up to 20 days maximum.
The LogTag TIC20 is factory pre-configured for one of a range of monitoring profiles. Special profiles are available on request, subject to conditions.
Statistical data can be downloaded from the TIC20 using an interface cradle and freely available LogTag Analyzer operating software if required.
The TIC20 offers an accurate and cost effective solution for monitoring the pharmaceutical cold chain in “last mile” distribution and other applications where full data logging capability is not required.
WHO PQS pre-qualified versions are also available.
Highlights
 
Monitoring Display Monitoring Display
LOAD OK LOAD REJECT
|
 |
Factory pre-configured to monitor a range of standard vaccines
|
 |
Standard 60 minute start delay
|
 |
Clear indication of temperature history/alarm status at all times.
|
 |
Up to 20 days temperature records can be viewed on the display
|
 |
Push button Start and Stop. Push Review button to display daily statistics in sequence.
|
 |
Data can be downloaded via an interface cradle and LogTag Analyzer if required.
|
 |
Robust and Accurate. Data collected is secure and cannot be manipulated.
|
 |
Fits easily into packages and can be mailed via letter rate.
|
 |
|
|
|
Specifications
|
Model#
|
|
TIC20
|
Operating temperature range
|
|
-30°C to +60°C (-22°F to +140°F)
|
Ambient humidity range during transport and use
|
|
0% to 95%RH
|
Rated Temperature reading accuracy
|
|
better than ±0.5°C for -10°C to +40°C (+14°F to +104°F)
better than ±1.0°C for -30°C to -10°C (-22°F to +14°F)
better than ±1.0°C for +40°C to +60°C (+104°F to +140°F)
|
Sensor reaction time (T90)
|
|
T90 less than 7 minutes by method detailed in EN12830:1999.
|
Display Resolution
|
|
0.1°C from -30°C ~ +60°C (0.2°F from -22°F to 100°F, 1°F from 100°F to 140°F)
|
Capacity
|
|
Minimum & maximum temperature for each of the 20 days. 1st activation of each alarm for each day including trigger time and duration of each excursion.
|
Sampling interval
|
|
Factory set to 6 minute interval (i.e. 0.1hour)
|
Memory type
|
|
Non volatile
|
Recordings
|
|
20 day statistics, temperature/time excursions and alarm trigger time and duration for each day.
|
Start Delay
|
|
Factory set to 60 minutes
|
Environmental
|
|
IEC 60529: IP64
|
Power source
|
|
3V Lithium-Manganese Dioxide, non replaceable
|
Battery life
|
|
Minimum storage life of 18 months before ‘start’. Monitoring period: 20 days. Minimum accessibility (display) period of 6 months after ‘stopped’
|
Size
|
|
73mm(H) x 54.5mm(W) x 8.6mm(T) (Volume < 34cm3)
|
Weight
|
|
30 grams
|
Case Material
|
|
Polycarbonate
|
Reader interface
|
|
LogTag TIC/TICT reader interface only
|
Calibration
|
|
Certificate of Traceability and Calibration to ISO/IEC17025 available on request.
|
Warranty
|
|
One year replaceable warranty against defects in materials and workmanship from the date of purchase. Excludes misuse or abuse of the product or as a result of unauthorized alteration or repairs.
|
Note: Resolution & Accuracy are rated values - actual product performance may be substantially better than figures stated.
|
Standards compliance
|
EMC Compliance
|
|
EC EMC directives (EN 61000-6-1:2005 & EN 61000-6-3:2006) Including electrostatic discharge as prescribed in EN 61000-4-2. Complies with FCC Part 15 Subparts A and B.
|
|
|
|
 |
|
Manufactured to meet the European RoHS Directive
The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment". This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants.
|
|
 |
|
INTERFACE CRADLE
The LogTag® TIC20/TICT reader interface is a special interface for reading the temperature indicator products and allows download of stored statistical & alarm trigger data for viewing & processing with LogTag Analyzer.
Details coming soon.
|
|
 |
|
Wall Mount Bracket
The LogTag® Wall Mount Bracket provides an easy and tidy solution to mounting a LogTag on a wall,door or vertical surface while still allowing easy removal of the LogTag for inspection or download.
Click here for Wall Mount Bracket details
|